Prostar Rack Mountable Line Interactive UPS 2000VA

Prostar PLR2K pure sine wave line interactive ups power supply 2000va

Rack Mountable Line Interactive UPS | 2KVA/1.2KW | 2U | 24VDC | 220Vad/230Vac/240Vac | Single Phase

SKU: PLR2K Category:

Prostar PLR2K 2U pure sine wave line interactive ups power supply 2000va provides maximum stability and superior compatibility with sensitive equipments.

Prostar Line interactive UPS is a full digital control of the design concept, application of intelligent CPU control System, combined with CMOS and PWM perfect, adopt frequency online interactive structure, built in power Intelligent charger novel uninterruptible power supply products. Adding an optional network management card permits remote management of the UPS, including reboots and activity logs.

Automatic voltage regulation (AVR) maintains 220V/230V/240V nominal output over an input range of 158V to 278V without using battery power. EMI/RFI noise filtering improves your equipment’s performance and prevents damage.

Pure sine wave line interactive UPS is required by some equipment power supplies and prevents others from overheating, malfunctioning or failing prematurely.

This line interactive ups connected mission-critical equipment against damage, downtime and data loss due to blackouts, brownouts, surges and line noise. Ideal solution for point-of-sale applications, VoIP systems and small business networks.

2U/3U Rack Mountable Line Interactive

Fig. 1 2U / 3U Rack Mountable Line Interactive

Line Interactive UPS Features & Benefits

1. Excellent microprocessor control guarantees high reliablility

Machine with CPU control, all the operational parameters of UPS are controlled by the CPU, ensuring the UPS is in the best working condition. Improved the accuracy of the product parameter, ensured full compliance of product performance, the product failure rate effectively reduce.

2. Intelligent Charger

Built-in smart charger, with TOP charge type (charging type of high current at the initial, and balanced type and floating type alternating charging), shorten the battery charging time, extend the battery life, and it is suit to the areas of high rate power cut. And the users can set charging voltage and charging current by press button.

3. Wide input voltage range (110V-300V)

Interactive structural design, low frequency type program, with superior shock resistance. To satisfy the demand for different type of load, this might be widely used in household, commercial, industrial, outdoor base station.

4. Special Protection method

Prostar line interactive takes muti-level protection mode of output, which could resisit the impact effectively, and also with the short circuit protection function, which could enhance its reliability.

Power Amplifier Over Current This system is equipped with the detection of the working current of power amplifier tube. When the detection current over large, the system will automatically enter current limiting working mode, meanwhile it displays the fault code E01.
Output Short Circuit Protection When the machine is shorted circuit, the system will shut down and display fault code: E02. After removed the fault, it needs to be started manually.
Overload Protection When the charge or inverter overload, the machine will enter the protection state, and display fault code: E03, including hardware protection and software protection.
Over Temperature Protection When the machine internal temperature is too high, the machine will enter the over-temperature protection state, and display fault code: E04.
Battery Over Voltage Protection In order to avoid the wrong way battery connection or the controller and charger fault caused system damage, when the system detects that battery voltage is over high, it will automatically shut down and display fault code: E05.
Low Battery Voltage Protection To avoid excessive battery discharge, the machine will automatically shut down the system and display fault code: E06.
Phase Reverse Protection When the system detects internal phase error, it will alarm and display fault code: E07.
Low Output Voltage Protection When the system detects that the output voltage of system is over low, the inverter will automatically shut down and display fault code: E08.
Hardware Protection When entering the hardware protection, the over current protector jumps off and needs to press the over current protector button before the machine can work again.
Software Protection When entering the software protection, the machine will shut down automatically through the software control. At this time, the user needs to start the machine manually.

5. Well unattended function

While the main power is abnormal, the battery will supply power instead till low-voltage appeared, and then UPS shut down; when the main power come back, the UPS will start working automatically, and it will charge for the battery at the same time. No need to turn on the UPS manually.

6. High Efficiency and Energy Saving

When AC power is normal, the inverter is under dormant status, the main power through the built-in voltage regulator (AVR) directly to supply power to the loads, and its efficiency is as high as 98%. Therefore it is called “Green UPS” which in full compliance with the spirit of low carton.

7. Auto restart while AC is recovering

8. Pure Sine Wave Output

Line interactive UPS pure sinewave output provides maximum stability and superior compatibility with sensitive equipment. Pure sine wave power is required by some equipment power supplies and prevents others from overheating, malfunctioning or failing prematurely.

9. Boost and buck AVR for voltage stabilization

10. Cold start function

11. LCD panel for comprehensive display

Front-panel LCD signals operating mode, load level, voltage, battery charge and estimated runtimes. Supports multiple advanced user setup and operating preferences.

Line Interactive UPS LCD Display Information

LCD Display Icons

Icon Function description
INPUT Vac Indicates the AC input voltage.
BATT Vdc Indicates the battery voltage.
OUTPUT Vac Indicates the output voltage.
INPUT Hz Indicates the AC input frequency.
BATT % Indicates the battery capacity.
OUTPUT % Indicates output loading.
full battery capacity Indicates battery level by 0-24%, 25-49%, 50-74% and 75-100% in battery mode and charging status in line mode.
In AC mode, it will present battery charging status.

Status Battery voltage LCD Display
Constant

Current mode /

Constant

Voltage mode

<2V/cell 4 bars will flash in turns.
2 ~ 2.1V/cell Bottom bar will be on and other three bars will flash in turns.
2.1 ~ 2.2V/cell Bottom two bars will be on and other two bars will flash in turns.
> 2.2 V/cell Bottom three bars will be on and the top bar will flash.
Floating mode. Batteries are fully charged. 4 bars will be on.

In battery mode, it will present battery capacity.

Load Percentage Battery Voltage LCD Display
Load >50% < 1.7V/cell 25% battery capacity
1.7V/cell ~ 1.8V/cell 50% battery capacity
1.8 ~ 1.9V/cell 75% battery capacity
> 1.9 V/cell full battery capacity
50%> Load > 20% < 1.8V/cell 25% battery capacity
1.8V/cell ~ 1.9V/cell 50% battery capacity
1.9 ~ 2.0V/cell 75% battery capacity
> 2.0 V/cell full battery capacity
Load < 20% < 1.9V/cell 25% battery capacity
1.8V/cell ~ 1.9V/cell 50% battery capacity
1.9 ~ 2.0V/cell 75% battery capacity
> 2.0 V/cell full battery capacity
 

100% Output loading

Indicates the load level by 0-24%, 25-50%, 51-74% and 75-100%.

0%~24%

25%~50% 51%~74%

75%~100%

25% Output loading 50% Output loading 75% Output loading Full Output loading
utility power Shows unit connects to the utility power.
utility charger circuit Indicates the utility charger circuit is working.
DC to AC Inverter working Shows the DC/AC inverter circuit is working.
working mode The working mode number.
alarm Indicates unit alarm is disabled.

Line Interactive UPS Details

2U Rack Mounted Line Interactive UPS Front Panel

Fig. 3 2U Rack Mounted Line Interactive UPS Front Panel

2U Rack Mounted Line Interactive UPS Rear

Fig. 4 2U Rack Mounted Line Interactive UPS Rear

Line Interactive UPS LCD Display

Fig. 5 Line Interactive UPS LCD Display

Line Interactive UPS Charging Function

Multi-stage charging: smart chip control of the three-stage battery charge management function, can quickly fill the battery, and effectively extend the battery life.

Charging current optional: regarding to their own configuration of the battery AH, the users select the corresponding charge current (from 0% -100% in 20 steps adjustable).

Charging voltage optional: for a variety of battery charging voltage: lead acid batteries, GEL batteries, Lithium batteries

Line Interactive UPS working mode

Mode Name Description
Mode 1 Regular Mode The system always keeps output.
Mode 4 Energy Saving

Mode

The system always keeps output.

The Articles You May Like

Product Tags:  ups power supply ups power supply 2000va pure sine wave
Request Product Price

Model PLR2K-24
Rated Power 2KVA/1200W
INPUT
Voltage Range 100V/110V/120V/127AC or 208V/220V/230V/240VAC(+25%,-36%)
Frequency Range 50/60 Hz±2.5Hz Auto
OUTPUT
AC Voltage Regulation 100V/110V/120V/127AC±0.5% or 208V/220V/230V/240VAC±0.5%(AC Mode±10%)
Frequency 50HZ/60HZ±0.5HZ Auto(AC Mode±2.5HZ)
Surge Power 3600W
Battery Efficiency 83%
AC Efficiency 93%
Transfer Time 8ms default, 4ms optional
Waveform Pure Sinewave
BATTERY
Battery Voltage 24VDC
Floating Charge Voltage 27.2VDC
Overcharge Protection 30.0VDC
AC Charge Current 0-20A Adjustable (20A default)
PROTECTION
Battery Reversal Optional
Output Short Circuit AC mode:Jump fuse, UPS mode: Shut down
Overload Full load 100%, UPS alarm. Overload 120%, UPS shut down output in 10s. Once the load back to normal, UPS recover output.
High AC Voltage Turn off AC,turn to UPS mode automatically
Low DC Voltage UPS shut down automatically,Once the AC recover, UPS turn on and charge automatically
Over Temperature Power Off
ENVIRONMENT
Humidity 15~93%(No condensation)
Temperature -10℃ ~ 50℃
Altitude ≤3000m
Communication USB, RS232, 485, SNMP (Optional)
MECHANICAL SPECIFICATIONS
Dimension, DxWxH (mm) 483×390×88 [2U]
Net Weight (Kgs/PC) 11.30
Product specifications are subject to change without further notice.