online ups 10kva 3 phase with battery backup

Prostar PHT3310B-PRO online ups 10kva 3 phase with battery backup

3 Phase High Frequency Online UPS | 10KVA/9KW | PF 0.9 | 3P/3P | 380Vac/400Vac/415Vac | Built-in 20Pcs 12V 9AH Battery

SKU: PHT3310B-PRO Category:

Prostar PHT3310B-PRO online ups 10kva 3 phase with integrated battery solution is the best solution for the power quality of any critical load.

High frequency data center online ups 10kva 3 phase offers features such as paralleling capability for both capacity and redundancy, full front access, included start up for ease of serviceability, user friendly graphical display with multiple language options, and SNMP with network based power management options.

Commercial high frequency online ups 10kva 3 phase is ensuring the safe operation of your critical loads. it is designed to meet the toughest application requirements and offers high reliability rectifier technology for sinusoidal input current and for reduced input current harmonic distortion (THDi).

3 Phase High Frequency Online UPS

UPS 10KVA 3 Phase Features & Benefits

High efficiency

  • High efficiency rates that remain stable even at lower operating power levels

Wide input voltage range

  • Designed for harsh electrical environments to save battery life

Output power factor 0.9

  • Offers higher performance and efficiency for critical applications

Advanced electrical features

  • Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high power efficiency

ECO Mode

  • Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection

Generator compatible

  • Ensures clean, uninterrupted power to protected equipment when generator power is used.

LCD graphics display

  • Text and mimic diagrams that display modes of operation, system parameters and alarms.

Predictive failure notification

  • Provides early-warning fault analysis ensuring proactive component replacement

Uninterruptible Power Supply Details

3P-3P PF0.9 Online UPS 10KVA 15KVA 20KVA Rear

APPLICATION

  • Telecommunication equipments
  • Biomedical equipments
  • Domestic electronic equipments
  • Network Operation Centres

The Articles You May Like

 

    Request Product Price

    MODELPHT3310B-PRO
    CAPACITY10KVA / 9KW
    Battery Voltage240VDC
    Size, D X W X H (mm)815x250x826
    Net Weight (kgs)109
    Phase3 Phase int / 3 Phase out
    INPUT
    Nominal Voltage380VAC/400VAC/415VAC (3Ph + N)
    Voltage Range190VAC – 520VAC @50% load; 305VAC – 478VAC @100% load
    Frequency Range46Hz ~ 54 Hz @ 50Hz; 56Hz ~ 64 Hz @ 60Hz
    Power Factor> [email protected]% load
    OUTPUT
    Output voltage380VAC/400VAC/415VAC (3Ph + N)
    AC Voltage Regulation± 1% (Batt. Mode)
    Frequency Range(Synchronized Range)46Hz ~ 54 Hz @ 50Hz
    56Hz ~ 64 Hz @ 60Hz
    Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz / 60 Hz ± 0.1 Hz
    OverloadAC Mode100% – 110%: 10mins; 110% – 130%: 1 min; > 130%: 1 sec
    Battery Mode100% – 110%: 30 sec; 110% – 130%: 10 sec; > 130%: 1 sec
    Current Crest Ratio3:1
    Harmonic Distortion< 2 % THD (Linear Load); < 5% THD (Non-linear Load)
    Transfer TimeAC Mode to Batt. Mode0 ms
    Inverter to Bypass0 ms
    Waveform (Batt. Mode)Pure Sine Wave
    EFFICIENCY
    AC Mode90.5%
    ECO Mode96.0%
    Battery Mode87.0%
    BATTERY
    Battery TypeLead Acid Battery, 12V 9AH
    Battery Numbers20Pcs default / (18 – 20 Pcs adjustable)*
    Recharge Time9 hours recover to 90% capacity
    Charging Current1.0A
    Charging Voltage273.0VDC ± 1%
    INDICATORS
    LCD DisplayUPS status, load level, battery level, Input/Output voltage, discharge timer, and fault conditions
    ALARM
    Battery ModeSounding every 4 seconds
    Low BatterySounding every second
    OverloadSounding twice every second
    FaultContinuously sounding
    ENVIRONMENT
    Operation Temperature0 – 40°C (battery life cycle will be shorten when temperature is above 25°C)
    Operation Humidity20-90 % RH @ 0- 40°C (non-condensing)
    Noise LevelLess than 60dBA @ 1 Meter
    MANAGEMENT
    Smart RS-232 or USBWindows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux, Unix and MAC
    Optional SNMPPower management from SNMP manager and web browser
    * When using inernal batteries from 18-19 Pcs, the unit will de-rate according to the below formula: P = PRating x N / 20.