High Frequency Online UPS | 10KVA/9000W | 192Vdc | 208V/220V/230V/240V | Without battery inside | Single phase
Prostar PHT1110B-PRO single phase networking 10kva ups battery backup systems provides early-warning fault analysis on batteries enabling timely preventive maintenance. It can protect connected loads from surges, spikes, lightning, and other power disturbances.
Between severe weather, the aging electrical grid and hazards lurking inside your own walls, your equipment is under constant attack from power problems. Even a brief loss of power or a momentary surge can ruin your equipment and destroy irreplaceable data. Prevent damage, downtime and data loss by installing 10kva ups systems. It conditions incoming AC power, provides enough battery backup to outlast most outages and automatically saves open files and shuts down computers gracefully during extended blackouts.
When the power goes out, 10kva ups provides guaranteed power for computers, external hard-drives and other electronics, including your wireless router so you can maintain a network connection for your IoT devices when you need it most! Ideal for the home and home offices, the online ups offers plenty of power and outlets.
Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Fig 1. Uninterruptible power supply front panel
Fig 2. Uninterruptible power supply rear
Fig 3. Uninterruptible power supply built-in battery
MODEL | PHT1110B-PRO | |
CAPACITY | 10KVA / 9000W | |
Battery Voltage | 192V | |
Size, D X W X H (mm) | 442 X 190 X 688 | |
Net Weight (kgs) | 66 | |
INPUT | ||
Norminal Voltage | 208/220/230/240VAC | |
Input Voltage Range | 120-300VAC (Based on load @50%) 180-300VAC (Based on load @100%) |
|
Frequency Range | 46Hz ~ 54Hz or 56Hz ~ 64Hz | |
Phase | Single Phase | |
Power Factor | ≧ 0.99 @ nominal voltage (input voltage) | |
OUTPUT | ||
Output voltage | 208/220/230/240VAC | |
AC Voltage Regulation | ± 1% (Batt. Mode) | |
Frequency Range(Synchronized Range) | 47Hz ~ 53 Hz @ 50Hz or 57Hz ~ 63 Hz @ 60Hz | |
Frequency Range (Batt. Mode) | 50 Hz or 60Hz ± 0.5% | |
Overload | 105%~110%: UPS shuts down after 10 min at battery mode or transfer to bypass when the utility is normal 110%~130%: UPS shuts down after 1min at battery mode or transfer to bypass when the utility is normal >130%:UPS shuts down after 3seconds at battery mode or transfer to bypass when the utility is normal |
|
Current Crest Ratio | 3:1 | |
Harmonic Distortion | ≦ 3 % THD (Linear Load);≦ 5% THD (Non-linear Load) | |
Transfer Time | AC Mode to Batt. Mode | 0 ms |
Inverter to Bypass | 0 ms | |
Waveform (Batt. Mode) | Pure Sine Wave | |
EFFICIENCY | ||
AC Mode | 93% | |
Battery Mode | 91% | |
BATTERY | ||
Battery Type | VRLA | |
Battery Numbers | 16 x 12V 9AH | |
Recharge Time | 4 hours recover to 90% capacity | |
Charging Current | 1A / 2A | |
Charging Voltage | 218.4VDC ± 1% | |
ENVIRONMENT | ||
Operation Humidity | 20-90 % RH @ 0- 40°C (non-condensing) | |
Noise Level | Less than 50dBA @ 1 Meter | |
MANAGEMENT | ||
Smart RS-232 or USB | Windows® 2000/2003/XP/Vista/2008、Windows® 7/8、Linux、Unix、MAC | |
Optional SNMP | Power management from SNMP manager and web browser |